(6 intermediate revisions by 2 users not shown) |
Line 1: |
Line 1: |
| The '''selected ion flow tube''', '''SIFT''', technique is a fast flow tube method for the study of the reactions of [[ion|ions]] (positive or negative) with atoms and molecules under truly thermalised conditions over a wide range of temperature. It has been extensively used to study ion-???????????????molecule kinetics. Its application to atmospheric and interstellar [[ion]] chemistry over a 20-year period has been crucial to the advancement and understanding of these interesting topics. Recently it has been developed as a very sensitive analytical technique '''SIFT-MS [[Selected Ion Flow Tube Mass Spectrometry]]''' for the quantification of trace gases in air and in human breath down to the ppb level in real time using [[Chemical Ionization]].
| | {{Final |
| | | |acronym=([[SIFT]]) |
| ===Instrumentation===
| | |def=Device in which ''[[m/z]]'' selected ions are entrained in an inert carrier gas and subsequently undergo [[ion/molecule reaction]]s with molecules introduced into the gas flow. |
| | | |rel=[[drift tube]] |
| '''The SIFT apparatus''' | | |ref=N. G. Adams, D. Smith. Int. J. Mass Spectrom. Ion Phys. 21, 349 (1976). (http://dx.doi.org/10.1016/0020-7381(76)80133-7 ) |
| | | }} |
| In the SIFT apparatus the ions are created in an [[ion source]] which is external to the flow tube. The ions are then extracted from the ion source, selected according to their mass-to-charge ratio using a [[quadrupole]] mass filter and injected into a flowing carrier gas (usually helium at a pressure of 0.5 Torr) via a small orifice ( ~1 mm diameter).
| |
| | |
| The carrier gas is inhibited from entering the quadrupole mass filter chamber by injecting it into the flow tube through a Venturi-type inlet at near-supersonic velocity in a direction away from the orifice. In this way a swarm of a single ion species thermalised at the same temperature as the carrier gas are convected along the flow tube ( ~1 m long), sampled by a downstream pinhole orifice, mass analysed and counted by a differentially-pumped quadrupole [[mass spectrometer]] system.
| |
| | |
| | |
| == Related Terms ==
| |
| | |
| [[Drift Tube]] | |
| | |
| | |
| == External Links == | |
| | |
| [http://www.keele.ac.uk/depts/stm/nirs/smith.htm Keele University]
| |
| | |
| [http://www.jh-inst.cas.cz/~spanel/sift.htm Heyrovsk???????????? Institute of Physical Chemistry]
| |
| | |
| [http://www.chem.yorku.ca/profs/bohme/research/et__MAIN.html York University]
| |
| | |
| [[Category:Ionization]] | | [[Category:Ionization]] |
|
| |
| [[Category:Reactions]] | | [[Category:Reactions]] |