Template:Ambient sampling: Difference between revisions

From Mass Spec Terms
No edit summary
Line 1: Line 1:
==Table of sampling-based ambient ionization techniques==
==Table of sampling-based ambient ionization techniques==
[[:Category:ambient ionization|Ambient ionization]] techniques that use ambient mechanical sampling, often in conjunction with a solvent.
[[:Category:ambient ionization|Ambient ionization]] techniques that use ambient sampling using solvent or mechanical means.
[[File:Ambient Extraction.jpg|thumb|left|500 px|Schematic of ambient sampling for mass spectrometry]]
[[File:Ambient Extraction.jpg|thumb|left|500 px|Schematic of ambient sampling for mass spectrometry]]


Line 10: Line 10:
! align="left" |Unique feature(s)
! align="left" |Unique feature(s)
! align="left" |Reference
! align="left" |Reference
|-
|[[EESI]]
|[[Extractive electrospray ionization]]
|[[Electrospray]]
|Droplet evaporation
|Aerosol sample
|(2006) {{doi}}10.1039/b602614a


|-
|-
Line 42: Line 50:
|
|
|(2009) {{doi}}10.1039/C0AN00312C  
|(2009) {{doi}}10.1039/C0AN00312C  
|-
|[[ND-EESI]]
|[[Neutral desorption extractive electrospray ionization]]
|[[Electrospray]]
|Droplet evaporation
|Aerosol produced by gas jet
|(2007) {{doi}}10.1002/jms.1282


|-
|-
Line 58: Line 74:
|
|
|(2010) {{doi}}10.1021/ac902854g
|(2010) {{doi}}10.1021/ac902854g
|-
|[[RADIO]]
|[[Radiofrequency acoustic desorption and ionization]]
|Aerosol
|[[Electrospray]]
|Aerosol produced by QCM
|(2008) {{doi}}10.1016/j.jasms.2008.11.024
|-
|[[RASTIR]]
|[[Remote analyte sampling transport and ionization relay]]
|Aerosol
|[[Electrospray]]
|Confined flow
|(2008) {{doi}}10.1021/ac800289f
|-
|[[REIMS]]
|[[Rapid evaporative ionization mass spectrometry]]
|Aerosol
|Droplet evaporation
|Surgical aerosol
|(2009) {{doi}}10.1002/anie.200902546


|-
|-

Revision as of 22:31, 5 October 2014

Table of sampling-based ambient ionization techniques

Ambient ionization techniques that use ambient sampling using solvent or mechanical means.

Schematic of ambient sampling for mass spectrometry
Acronym Technique Sampling Ionization Unique feature(s) Reference
EESI Extractive electrospray ionization Electrospray Droplet evaporation Aerosol sample (2006) http://dx.doi.org/10.1039/b602614a
ESTASI Electrostatic spray ionization Liquid microjunction Electrospray Direct ESI at contact (2014) http://dx.doi.org/10.1021/ac4031779
LESA Liquid extraction surface analysis Liquid microjunction Electrospray Commercial product (2010) http://dx.doi.org/10.1021/ac901098d
LMJ-SSP Liquid microjunction-surface sampling probe Liquid microjunction Electrospray (2010) http://dx.doi.org/10.1021/ac901098d
nano-DESI Nanospray desorption electrospray ionization Liquid microjunction Electrospray (2009) http://dx.doi.org/10.1039/C0AN00312C
ND-EESI Neutral desorption extractive electrospray ionization Electrospray Droplet evaporation Aerosol produced by gas jet (2007) http://dx.doi.org/10.1002/jms.1282
PESI Probe electrospray ionization Mechanical Electrospray (2007) http://dx.doi.org/10.1002/rcm.3201
PS Paper spray Deposition Electrospray (2010) http://dx.doi.org/10.1021/ac902854g
RADIO Radiofrequency acoustic desorption and ionization Aerosol Electrospray Aerosol produced by QCM (2008) http://dx.doi.org/10.1016/j.jasms.2008.11.024
RASTIR Remote analyte sampling transport and ionization relay Aerosol Electrospray Confined flow (2008) http://dx.doi.org/10.1021/ac800289f
REIMS Rapid evaporative ionization mass spectrometry Aerosol Droplet evaporation Surgical aerosol (2009) http://dx.doi.org/10.1002/anie.200902546
RoPPI Robotic plasma probe ionization Mechanical Electrospray Robotic arm (2014) http://dx.doi.org/10.1039/c4an00277f