Template:Ambient sampling: Difference between revisions
From Mass Spec Terms
No edit summary |
|||
(13 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
==Table of | ==Table of sampling-based ambient ionization techniques== | ||
[[:Category:ambient ionization|Ambient ionization]] techniques that use non-laser ambient sampling with electrospray or other post-ionization. | |||
[[File:Ambient Extraction.jpg|thumb|left|500 px|Schematic of ambient sampling for mass spectrometry]] | |||
[[File:Ambient Extraction.jpg|thumb|left|500 px|Schematic of | |||
{|class="wikitable sortable" cellpadding="15" border="1" cellspacing="0" width="85%" | {|class="wikitable sortable" cellpadding="15" border="1" cellspacing="0" width="85%" | ||
Line 11: | Line 10: | ||
! align="left" |Unique feature(s) | ! align="left" |Unique feature(s) | ||
! align="left" |Reference | ! align="left" |Reference | ||
|- | |||
|[[EESI]] | |||
|[[Extractive electrospray ionization]] | |||
|Aerosol | |||
|[[Electrospray]] | |||
|Aerosol sample | |||
|(2006) {{doi}}10.1039/b602614a | |||
|- | |||
|[[ESA-Py]] | |||
|[[Electrospray-assisted pyrolysis ionization]] | |||
|Pyrolysis | |||
|[[Electrospray]] | |||
| | |||
|(2005) {{doi}}10.1021/ac051116m | |||
|- | |||
|[[ESTASI]] | |||
|[[Electrostatic spray ionization]] | |||
|[[Liquid microjunction]] | |||
|[[Electrospray]] | |||
|Direct [[ESI]] at contact | |||
|(2014) {{doi}}10.1021/ac4031779 | |||
|- | |- | ||
Line 17: | Line 40: | ||
|[[Liquid microjunction]] | |[[Liquid microjunction]] | ||
|[[Electrospray]] | |[[Electrospray]] | ||
| | |Commercial product | ||
| | |(2010) {{doi}}10.1021/ac901098d | ||
|- | |- | ||
Line 26: | Line 49: | ||
|[[Electrospray]] | |[[Electrospray]] | ||
| | | | ||
|{{doi}}10.1021/ac901098d | |(2010) {{doi}}10.1021/ac901098d | ||
|- | |- | ||
Line 34: | Line 57: | ||
|[[Electrospray]] | |[[Electrospray]] | ||
| | | | ||
|{{doi}}10.1039/C0AN00312C | |(2009) {{doi}}10.1039/C0AN00312C | ||
|- | |||
|[[ND-EESI]] | |||
|[[Neutral desorption extractive electrospray ionization]] | |||
|[[Electrospray]] | |||
|Droplet evaporation | |||
|Aerosol produced by gas jet | |||
|(2007) {{doi}}10.1002/jms.1282 | |||
|- | |- | ||
Line 42: | Line 73: | ||
|[[Electrospray]] | |[[Electrospray]] | ||
| | | | ||
|{{doi}}10.1002/rcm.3201 | |(2007) {{doi}}10.1002/rcm.3201 | ||
|- | |- | ||
Line 50: | Line 81: | ||
|[[Electrospray]] | |[[Electrospray]] | ||
| | | | ||
|{{doi}}10.1021/ac902854g | |(2010) {{doi}}10.1021/ac902854g | ||
|- | |||
|[[RADIO]] | |||
|[[Radiofrequency acoustic desorption and ionization]] | |||
|Aerosol | |||
|[[Electrospray]] | |||
|Aerosol produced by QCM | |||
|(2008) {{doi}}10.1016/j.jasms.2008.11.024 | |||
|- | |||
|[[RASTIR]] | |||
|[[Remote analyte sampling transport and ionization relay]] | |||
|Aerosol | |||
|[[Electrospray]] | |||
|Confined flow | |||
|(2008) {{doi}}10.1021/ac800289f | |||
|- | |||
|[[REIMS]] | |||
|[[Rapid evaporative ionization mass spectrometry]] | |||
|Aerosol | |||
|Droplet evaporation | |||
|Surgical aerosol | |||
|(2009) {{doi}}10.1002/anie.200902546 | |||
|- | |||
|[[RoPPI]] | |||
|[[Robotic plasma probe ionization]] | |||
|Mechanical | |||
|[[Electrospray]] | |||
|Robotic arm | |||
|(2014) {{doi}}10.1039/c4an00277f | |||
|} | |} |
Latest revision as of 22:48, 5 October 2014
Table of sampling-based ambient ionization techniques
Ambient ionization techniques that use non-laser ambient sampling with electrospray or other post-ionization.
