Template:Ambient sampling: Difference between revisions
From Mass Spec Terms
| No edit summary | |||
| (8 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| ==Table of sampling-based ambient ionization techniques== | ==Table of sampling-based ambient ionization techniques== | ||
| [[:Category:ambient ionization|Ambient ionization]] techniques that use non-laser ambient sampling with electrospray or other post-ionization. | |||
| [[File:Ambient Extraction.jpg|thumb|left|500 px|Schematic of ambient sampling for mass spectrometry]] | [[File:Ambient Extraction.jpg|thumb|left|500 px|Schematic of ambient sampling for mass spectrometry]] | ||
| {|class="wikitable sortable" cellpadding="15" border="1" cellspacing="0" width="85%" | {|class="wikitable sortable" cellpadding="15" border="1" cellspacing="0" width="85%" | ||
| Line 12: | Line 10: | ||
| ! align="left" |Unique feature(s) | ! align="left" |Unique feature(s) | ||
| ! align="left" |Reference | ! align="left" |Reference | ||
| |- | |||
| |[[EESI]] | |||
| |[[Extractive electrospray ionization]] | |||
| |Aerosol | |||
| |[[Electrospray]] | |||
| |Aerosol sample | |||
| |(2006) {{doi}}10.1039/b602614a | |||
| |- | |||
| |[[ESA-Py]] | |||
| |[[Electrospray-assisted pyrolysis ionization]] | |||
| |Pyrolysis | |||
| |[[Electrospray]] | |||
| | | |||
| |(2005) {{doi}}10.1021/ac051116m | |||
| |- | |||
| |[[ESTASI]] | |||
| |[[Electrostatic spray ionization]] | |||
| |[[Liquid microjunction]] | |||
| |[[Electrospray]] | |||
| |Direct [[ESI]] at contact | |||
| |(2014) {{doi}}10.1021/ac4031779 | |||
| |- | |- | ||
| Line 19: | Line 41: | ||
| |[[Electrospray]] | |[[Electrospray]] | ||
| |Commercial product | |Commercial product | ||
| | | |(2010) {{doi}}10.1021/ac901098d  | ||
| |- | |- | ||
| Line 27: | Line 49: | ||
| |[[Electrospray]] | |[[Electrospray]] | ||
| | | | | ||
| |{{doi}}10.1021/ac901098d | |(2010) {{doi}}10.1021/ac901098d | ||
| |- | |- | ||
| Line 35: | Line 57: | ||
| |[[Electrospray]] | |[[Electrospray]] | ||
| | | | | ||
| |{{doi}}10.1039/C0AN00312C   | |(2009) {{doi}}10.1039/C0AN00312C   | ||
| |- | |||
| |[[ND-EESI]] | |||
| |[[Neutral desorption extractive electrospray ionization]] | |||
| |[[Electrospray]] | |||
| |Droplet evaporation | |||
| |Aerosol produced by gas jet | |||
| |(2007) {{doi}}10.1002/jms.1282 | |||
| |- | |- | ||
| Line 43: | Line 73: | ||
| |[[Electrospray]] | |[[Electrospray]] | ||
| | | | | ||
| |{{doi}}10.1002/rcm.3201 | |(2007) {{doi}}10.1002/rcm.3201 | ||
| |- | |- | ||
| Line 51: | Line 81: | ||
| |[[Electrospray]] | |[[Electrospray]] | ||
| | | | | ||
| |{{doi}}10.1021/ac902854g | |(2010) {{doi}}10.1021/ac902854g | ||
| |- | |||
| |[[RADIO]] | |||
| |[[Radiofrequency acoustic desorption and ionization]] | |||
| |Aerosol | |||
| |[[Electrospray]] | |||
| |Aerosol produced by QCM | |||
| |(2008) {{doi}}10.1016/j.jasms.2008.11.024 | |||
| |- | |||
| |[[RASTIR]] | |||
| |[[Remote analyte sampling transport and ionization relay]] | |||
| |Aerosol | |||
| |[[Electrospray]] | |||
| |Confined flow | |||
| |(2008) {{doi}}10.1021/ac800289f  | |||
| |- | |||
| |[[REIMS]] | |||
| |[[Rapid evaporative ionization mass spectrometry]] | |||
| |Aerosol | |||
| |Droplet evaporation | |||
| |Surgical aerosol | |||
| |(2009) {{doi}}10.1002/anie.200902546 | |||
| |- | |||
| |[[RoPPI]] | |||
| |[[Robotic plasma probe ionization]] | |||
| |Mechanical | |||
| |[[Electrospray]] | |||
| |Robotic arm | |||
| |(2014) {{doi}}10.1039/c4an00277f | |||
| |} | |} | ||
Latest revision as of 22:48, 5 October 2014
Table of sampling-based ambient ionization techniques
Ambient ionization techniques that use non-laser ambient sampling with electrospray or other post-ionization.

