Ion cyclotron resonance mass spectrometer: Difference between revisions

From Mass Spec Terms
No edit summary
 
No edit summary
 
(17 intermediate revisions by 2 users not shown)
Line 1: Line 1:
== [[Orange Book]] Entry ==
<!-- Orange Book -->
 
{{orange|
A high-frequency mass spectrometer in which the ions to be detected, with a selected
A high-frequency mass spectrometer in which the ions to be detected, with a selected
[[mass/charge ratio]], absorb maximum energy through the effect of a high-frequency field
[[mass/charge ratio]], absorb maximum energy through the effect of a high-frequency field
and a constant magnetic field perpendicular to it. Maximum energy is gained by ions
and a constant magnetic field perpendicular to it. Maximum energy is gained by ions
that satisfy the cyclotron resonance condition and as a result these are separated from
that satisfy the cyclotron resonance condition and as a result these are separated from
ions of different mass/charge. See also [[Fourier transform ion cyclotron mass
ions of different mass/charge. See also [[Fourier transform ion cyclotron mass spectrometer]] and [[ion trap]].
spectrometer]] and [[ion trap]].
}}
 
<!-- Gold Book -->
{{gold|
http://goldbook.iupac.org/I03162.html
 
A high-frequency mass spectrometer in which the ions to be detected, with a selected value of the quotient mass/charge, absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different mass/charge.
 
'''Source''':
 
PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545
 
[[Orange Book]], p. 202
}}
 


== Proposed New Entry ==


(there is no new entry yet)
[[Category:M/z Separation]]
{{DEFAULTSORT:Ion Cyclotron Resonance Mass Spectrometer}}
[[Category:Orange Book term]]
[[Category:Mass spectrometer type]]

Latest revision as of 11:40, 6 August 2025

Orange Book

ORANGE BOOK DEFINITION

IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023)

Ion cyclotron resonance mass spectrometer

A high-frequency mass spectrometer in which the ions to be detected, with a selected mass/charge ratio, absorb maximum energy through the effect of a high-frequency field and a constant magnetic field perpendicular to it. Maximum energy is gained by ions that satisfy the cyclotron resonance condition and as a result these are separated from ions of different mass/charge. See also Fourier transform ion cyclotron mass spectrometer and ion trap.

IUPAC 1997 Orange Book Chapter 12
Index of Orange Book Terms


Gold Book

GOLD BOOK DEFINITION

IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997).

Ion cyclotron resonance mass spectrometer

http://goldbook.iupac.org/I03162.html

A high-frequency mass spectrometer in which the ions to be detected, with a selected value of the quotient mass/charge, absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different mass/charge.

Source:

PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545

Orange Book, p. 202

IUPAC Gold Book
Index of Gold Book Terms