Ion cyclotron resonance mass spectrometer: Difference between revisions
→Orange Book entry: add Orange Book cat using AWB |
No edit summary |
||
(7 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
<!-- Orange Book --> | |||
{{orange| | {{orange| | ||
A high-frequency mass spectrometer in which the ions to be detected, with a selected | A high-frequency mass spectrometer in which the ions to be detected, with a selected | ||
Line 9: | Line 7: | ||
ions of different mass/charge. See also [[Fourier transform ion cyclotron mass spectrometer]] and [[ion trap]]. | ions of different mass/charge. See also [[Fourier transform ion cyclotron mass spectrometer]] and [[ion trap]]. | ||
}} | }} | ||
<!-- Gold Book --> | |||
{{gold| | |||
http://goldbook.iupac.org/I03162.html | |||
A high-frequency mass spectrometer in which the ions to be detected, with a selected value of the quotient mass/charge, absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different mass/charge. | |||
'''Source''': | |||
PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545 | |||
[[Orange Book]], p. 202 | |||
}} | |||
[[Category:M/z Separation]] | [[Category:M/z Separation]] | ||
{{DEFAULTSORT:Ion Cyclotron Resonance Mass Spectrometer}} | {{DEFAULTSORT:Ion Cyclotron Resonance Mass Spectrometer}} | ||
[[Category:Orange | [[Category:Orange Book term]] | ||
[[Category:Mass spectrometer type]] |
Latest revision as of 11:40, 6 August 2025
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
Ion cyclotron resonance mass spectrometer |
---|
A high-frequency mass spectrometer in which the ions to be detected, with a selected mass/charge ratio, absorb maximum energy through the effect of a high-frequency field and a constant magnetic field perpendicular to it. Maximum energy is gained by ions that satisfy the cyclotron resonance condition and as a result these are separated from ions of different mass/charge. See also Fourier transform ion cyclotron mass spectrometer and ion trap. |
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
Gold Book
GOLD BOOK DEFINITION
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). |
Ion cyclotron resonance mass spectrometer |
---|
http://goldbook.iupac.org/I03162.html A high-frequency mass spectrometer in which the ions to be detected, with a selected value of the quotient mass/charge, absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different mass/charge. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545 Orange Book, p. 202 |
IUPAC Gold Book |
Index of Gold Book Terms |