Category:Reaction monitoring: Difference between revisions
From Mass Spec Terms
|  Created page with "Category:Reactions" | No edit summary | ||
| (4 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| ===IUPAC reaction monitoring terms=== | |||
| :{| class="wikitable"  border="1" style="border-collapse:collapse;" style="border-spacing: 1px; border: 5px solid purple;" | |||
| |- | |||
| ! Term | |||
| !Acronym | |||
| ! Definition | |||
| ! Diagram | |||
| ! Reference | |||
| |- | |||
| |[[Selected ion monitoring]] | |||
| |[[SIM]] | |||
| |Operation of a [[mass spectrometer]] in which the abundances of [[ion]]s of one or more specific ''[[m/z]]'' values are recorded rather than the entire [[mass spectrum]].  | |||
| |     <big><big> </big></big> | |||
| |[[Gold Book]] | |||
| |- | |||
| | [[Selected reaction monitoring]] | |||
| |[[SRM]] | |||
| | Data acquired from one or more specific product [[ion]]s corresponding to [[m/z]] selected [[precursor ion]]s recorded via two or more stages of [[mass spectrometry]]. | |||
| :''Note 1'': Selected reaction monitoring in [[multiple-stage mass spectrometry]] is known as [[consecutive reaction monitoring]]. | |||
| :''Note 2'': Selected reaction monitoring applied to multiple product ions from one or more [[precursor ion]]s is known as multiple reaction monitoring. | |||
| |[[File:SRM.jpg|center|20 px]] | |||
| |de Hoffmann. J. Mass Spectrom. 31, 129 (1996). | |||
| |- | |||
| | [[Consecutive reaction monitoring]] | |||
| |[[CRM]] | |||
| | [[Multiple-stage mass spectrometry]] experiment with three or more stages of [[m/z]] separation in which products of sequential fragmentation or bimolecular reactions are selected for detection. | |||
| |[[File:CRM.jpg|center|20 px]] | |||
| |Tomer, Guenat, Deterding. Anal. Chem. 60, 2232 (1988).  | |||
| |- | |||
| |[[Multiple reaction monitoring]] | |||
| |[[MRM]] | |||
| |Application of [[selected reaction monitoring]] to multiple [[product ion]]s from one or more [[precursor ion]]s.  | |||
| :Note: This term should not be confused with [[consecutive reaction monitoring]], which involves the serial application of three or more stages of selected reaction monitoring. | |||
| |[[File:MRM-Single.jpg|center|30 px]] | |||
| |Roepstorff, Fohlman. Biomed. Mass Spectrom. 11, 601 (1984). | |||
| |} | |||
| [[Category:Reactions]] | [[Category:Reactions]] | ||
| [[Category:Fragmentation]] | |||
| [[Category:mass spectrometry terms]] | |||
Latest revision as of 17:35, 31 March 2024
IUPAC reaction monitoring terms
- Term - Acronym - Definition - Diagram - Reference - Selected ion monitoring - SIM - Operation of a mass spectrometer in which the abundances of ions of one or more specific m/z values are recorded rather than the entire mass spectrum. - Gold Book - Selected reaction monitoring - SRM - Data acquired from one or more specific product ions corresponding to m/z selected precursor ions recorded via two or more stages of mass spectrometry. - Note 1: Selected reaction monitoring in multiple-stage mass spectrometry is known as consecutive reaction monitoring.
- Note 2: Selected reaction monitoring applied to multiple product ions from one or more precursor ions is known as multiple reaction monitoring.
  - de Hoffmann. J. Mass Spectrom. 31, 129 (1996). - Consecutive reaction monitoring - CRM - Multiple-stage mass spectrometry experiment with three or more stages of m/z separation in which products of sequential fragmentation or bimolecular reactions are selected for detection.  - Tomer, Guenat, Deterding. Anal. Chem. 60, 2232 (1988). - Multiple reaction monitoring - MRM - Application of selected reaction monitoring to multiple product ions from one or more precursor ions. - Note: This term should not be confused with consecutive reaction monitoring, which involves the serial application of three or more stages of selected reaction monitoring.
  - Roepstorff, Fohlman. Biomed. Mass Spectrom. 11, 601 (1984). 
Pages in category "Reaction monitoring"
The following 36 pages are in this category, out of 36 total.