Prolate trochoidal mass spectrometer: Difference between revisions
No edit summary |
rm section heads , Replaced: == Orange Book entry == ‚Üí <!-- Orange Book -->, == Gold Book entry == ‚Üí <!-- Gold Book -->, using AWB |
||
Line 5: | Line 5: | ||
}} | }} | ||
<!-- Orange Book --> | |||
{{orange| | {{orange| | ||
A [[mass spectrometer]] in which the ions of different [[mass/charge ratio]]s are separated by means of crossed electric and magnetic fields in such a way that the selected ions follow a prolate trochoidal path. The commonly used term ????????????????????????cycloidal?????????????????????? is incorrect and should not be used as the path is not cycloidal. (A cycloid is a special case of a trochoid). See crossed electric and magnetic fields. | A [[mass spectrometer]] in which the ions of different [[mass/charge ratio]]s are separated by means of crossed electric and magnetic fields in such a way that the selected ions follow a prolate trochoidal path. The commonly used term ????????????????????????cycloidal?????????????????????? is incorrect and should not be used as the path is not cycloidal. (A cycloid is a special case of a trochoid). See crossed electric and magnetic fields. | ||
}} | }} | ||
<!-- Gold Book --> | |||
{{gold| | {{gold| | ||
http://goldbook.iupac.org/P04874.html | http://goldbook.iupac.org/P04874.html |
Revision as of 13:18, 18 July 2009
Obsolete Template
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
Prolate trochoidal mass spectrometer |
---|
A mass spectrometer in which the ions of different mass/charge ratios are separated by means of crossed electric and magnetic fields in such a way that the selected ions follow a prolate trochoidal path. The commonly used term ????????????????????????cycloidal?????????????????????? is incorrect and should not be used as the path is not cycloidal. (A cycloid is a special case of a trochoid). See crossed electric and magnetic fields. |
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
Gold Book
GOLD BOOK DEFINITION
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). |
Prolate trochoidal mass spectrometer |
---|
http://goldbook.iupac.org/P04874.html A mass spectrometer in which ions of different mass/charge are separated by means of crossed electric and magnetic fields in such a way that the selected ions follow a prolate trochoidal path. The usual term 'cycloidal' used sometimes is incorrect because the path used is not cycloidal. A cycloid is a special case of a trochoid. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545 Orange Book, p. 203 |
IUPAC Gold Book |
Index of Gold Book Terms |