| {{DefName|A mass spectrometer based on the principle of ion cyclotron resonance. An ion placed in a magnetic field will move in a circular orbit at a frequency characteristic of its m/z value. Ions are excited to a coherent orbit using a pulse of radio frequency energy and their image charge is detected on receiver plates as a time domain signal.  Fourier transformation of the time domain signal results in the frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and m/z, can be converted to a mass spectrum.}} | {{DefName|A [[mass spectrometer]] based on the principle of [[ion cyclotron resonance]]. An ion placed in a magnetic field will move in a circular orbit at a frequency characteristic of its ''[[m/z]]'' value. Ions are excited to a coherent orbit using a pulse of radio frequency energy and their image charge is detected on receiver plates as a time domain signal.  Fourier transformation of the time domain signal results in the frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and ''[[m/z]]'', can be converted to a [[mass spectrum]].}} | ||
| == [[Orange Book]] Entry == | == [[Orange Book]] Entry == | ||
| Line 7: | Line 7: | ||
| == External Links == | == External Links == | ||
| [http://xlink.rsc.org/?DOI=b403880k Principles of Fourier transform ion cyclotron resonance mass spectrometry and its application in structural biology] | *[http://xlink.rsc.org/?DOI=b403880k Principles of Fourier transform ion cyclotron resonance mass spectrometry and its application in structural biology] | ||
| [[Category:m/z Separation]] | [[Category:m/z Separation]] | ||
Revision as of 16:33, 30 November 2005
| DRAFT DEFINITION | 
| Fourier transform-ion cyclotron resonance-mass spectrometer | 
|---|
| A mass spectrometer based on the principle of ion cyclotron resonance. An ion placed in a magnetic field will move in a circular orbit at a frequency characteristic of its m/z value. Ions are excited to a coherent orbit using a pulse of radio frequency energy and their image charge is detected on receiver plates as a time domain signal. Fourier transformation of the time domain signal results in the frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and m/z, can be converted to a mass spectrum. | 
| Considered between 2004 and 2006 but not included in the 2006 PAC submission | 
| This is an unofficial draft definition presented for information and comment. | 
Orange Book Entry
A high-frequency mass spectrometer in which the cyclotron motion of ions, having different mass/charge ratios, in a constant magnetic field, is excited essentially simultaneously and coherently by a pulse of a radio-frequency electric field applied perpendicularly to the magnetic field. The excited cyclotron motion of the ions is subsequently detected on receiver plates as a time domain signal that contains all the cyclotron frequencies excited. Fourier transformation of the time domain signal results in the frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and mass/charge ratio, can be converted to a mass spectrum. See also ion cyclotron resonance (ICR) mass spectrometer.