Linked scan: Difference between revisions
From Mass Spec Terms
, Replaced: == Related Terms == ‚Üí == See also ==, using AWB |
clean up using AWB |
||
Line 2: | Line 2: | ||
A scan in a [[tandem mass spectrometer]] with two or more m/z analyzers or in a [[sector mass spectrometer]] that incorporates at least one [[magnetic sector]] and one [[electric sector]]. Two or more of the analyzers are scanned simultaneously so as to preserve a predetermined relationship between scan parameters to produce a [[product ion]], [[precursor ion]] or constant neutral loss or gain spectrum. | A scan in a [[tandem mass spectrometer]] with two or more m/z analyzers or in a [[sector mass spectrometer]] that incorporates at least one [[magnetic sector]] and one [[electric sector]]. Two or more of the analyzers are scanned simultaneously so as to preserve a predetermined relationship between scan parameters to produce a [[product ion]], [[precursor ion]] or constant neutral loss or gain spectrum. | ||
}} | }} | ||
== Orange Book Entry == | == Orange Book Entry == | ||
Line 25: | Line 24: | ||
}} | }} | ||
== See also == | == See also == | ||
*[[Linked Scan at Constant B2/E]] | *[[Linked Scan at Constant B2/E]] | ||
*[[Linked Scan At Constant B/E]] | *[[Linked Scan At Constant B/E]] | ||
*[[Linked scan At Constant B(1-(E/E0))1/2/E]] | *[[Linked scan At Constant B(1-(E/E0))1/2/E]] | ||
*[[Linked Scan at Constant B2(E0-E)]] | *[[Linked Scan at Constant B2(E0-E)]] | ||
*[[Linked Scan at Constant E2/V]] | *[[Linked Scan at Constant E2/V]] | ||
*[[Sector Mass Spectrometer]] | *[[Sector Mass Spectrometer]] | ||
*[[Electric Sector]] | *[[Electric Sector]] | ||
*[[Magnetic Sector]] | *[[Magnetic Sector]] | ||
== External links == | == External links == | ||
*[http://www3.interscience.wiley.com/cgi-bin/abstract/110441058/ABSTRACT A new linked scan for reversed geometry mass spectrometers (Article) ] | *[http://www3.interscience.wiley.com/cgi-bin/abstract/110441058/ABSTRACT A new linked scan for reversed geometry mass spectrometers (Article) ] | ||
[[Category:M/z Separation]] | [[Category:M/z Separation]] | ||
[[Category:Sequential m/z Separation]] | [[Category:Sequential m/z Separation]] | ||
{{DEFAULTSORT:Linked Scan}} | {{DEFAULTSORT:Linked Scan}} |
Revision as of 18:55, 12 July 2009
Obsolete Template
Orange Book Entry
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
Linked scan |
---|
A scan in an instrument comprising two or more analysers in which two or more of the analyser fields are scanned simultaneously so as to preserve a predetermined relationship between parameters characterizing these fields. While these parameters are commonly field strengths, they may also be frequencies in analysers where alternating fields are employed.
|
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
See also
- Linked Scan at Constant B2/E
- Linked Scan At Constant B/E
- Linked scan At Constant B(1-(E/E0))1/2/E
- Linked Scan at Constant B2(E0-E)
- Linked Scan at Constant E2/V
- Sector Mass Spectrometer
- Electric Sector
- Magnetic Sector