Ion cyclotron resonance mass spectrometer: Difference between revisions
No edit summary |
No edit summary |
||
| Line 2: | Line 2: | ||
A [[mass spectrometer]] in which the ions to be detected, with a selected value of [[m/z]], absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different m/z. | A [[mass spectrometer]] in which the ions to be detected, with a selected value of [[m/z]], absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different m/z. | ||
Related term: | Related term: [[Fourier transform ion cyclotron resonance mass spectrometer]]. | ||
| | | | ||
#[[Orange Book]] | #[[Orange Book]] | ||
Revision as of 22:08, 1 June 2010
This template is no longer used.
Orange Book
| ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
| Ion cyclotron resonance mass spectrometer |
|---|
|
A high-frequency mass spectrometer in which the ions to be detected, with a selected mass/charge ratio, absorb maximum energy through the effect of a high-frequency field and a constant magnetic field perpendicular to it. Maximum energy is gained by ions that satisfy the cyclotron resonance condition and as a result these are separated from ions of different mass/charge. See also Fourier transform ion cyclotron mass spectrometer and ion trap. |
| IUPAC 1997 Orange Book Chapter 12 |
| Index of Orange Book Terms |
Gold Book
| GOLD BOOK DEFINITION
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). |
| Ion cyclotron resonance mass spectrometer |
|---|
|
http://goldbook.iupac.org/I03162.html A high-frequency mass spectrometer in which the ions to be detected, with a selected value of the quotient mass/charge, absorb maximum energy through the effect of a high-frequency electric field and a constant magnetic field perpendicular to the electric field. Maximum energy is gained by the ions which satisfy the cyclotron resonance condition and as a result they are separated from ions of different mass/charge. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545 Orange Book, p. 202 |