Arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/2 radians in a radial [[electric field]] analyzer is followed by a [[magnetic deflection]] of π/3 radians. | Arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/2 radians in a radial [[electric field]] analyzer is followed by a [[magnetic deflection]] of π/3 radians. | ||
}} | }} | ||
{{Rev5| | |||
Arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic energy analyzer is combined with a magnetic deflection of π/3 radians. | |||
Related term: Mattauch-Herzog geometry. | |||
| | |||
#[[Orange Book]] | |||
#[[Gold Book]] | |||
}} | |||
<!-- Orange Book --> | <!-- Orange Book --> | ||
{{orange| | {{orange| | ||
An arrangement for a [[ | An arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a [[magnetic deflection]] of π/3 radians. The [[electrostatic analyser]] uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. | ||
}} | }} | ||
{{gold| | |||
http://goldbook.iupac.org/N04141.html | |||
An arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a magnetic deflection of π/3 radians. The electrostatic analyser uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. | |||
Source: | |||
PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | |||
[[Orange Book]], p. 201 | |||
}} | |||
== See also == | == See also == | ||
*[[Double-focusing mass spectrometer]] | *[[Double-focusing mass spectrometer]] |
Revision as of 22:09, 6 June 2010
Obsolete Template
This template is no longer used.
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
Nier-Johnson geometry |
---|
An arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a magnetic deflection of π/3 radians. The electrostatic analyser uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. |
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
Gold Book
GOLD BOOK DEFINITION
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). |
Nier-Johnson geometry |
---|
http://goldbook.iupac.org/N04141.html An arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a magnetic deflection of π/3 radians. The electrostatic analyser uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 Orange Book, p. 201 |
IUPAC Gold Book |